Usbellows logo.png
EJMA Logo

US Bellows is a Standards Subscriber | Exp: Dec 31, 2026 | See ejma.org to check verification process
Celebrating over 20 years of EJMA membership

If a simple bellows is designed without limit rods (for operating cases), under a hydro test, do you recommend adding limit rods?

Yes, if they are testing just the expansion joint or if they are testing when installed, they have to make sure that the pipe line is anchored or have limit rods added to the expansion joint to absorb the pressure thrust.

91578a1
Single Metallic Expansion Joints with Limit Rods